Premier Internal FD30 Veneer Fire Door Set - PAS24


Size
Color
Frame size

 

Technical Specification

DOORSET
Door hung on 3 hinges in assembled frame up to 2100 high
Door hung on 4 hinges in assembled frame above 2100 high*
Lock, keeps and intumescent fitted
15mm thick hardwood threshold to bottom of frame
25 x 4mm Intumescent to bottom edge of door
1no 10 x 4 Pyro-plex White Intumescent seal to frame
1no 10 x 4 Pyro-plex White Intumescent twin flipper smoke seal to frame
Intumescent hinge pads to all hinge blades door & frame
IRONMONGERY INCLUDED WITH DOOR SET
102 x 76 x 3mm Grade 13 BB SSS Radius Hinges
Winkhaus AV2 3 Point locking system - 55mm Backset
ArmorPlate Gearbox 024 - to surround lock case
Winkhaus AV2 pocket keep to top and bottom 
Winkhaus AV2 centre keep 
33/33 Nickel Kitemark XR6 Cylinder & thumbturn (3 star)
Palladio Quickfit Lever Silver - Lever Handle set
Hoppe Arrone AR1500SE Door closer & Matching arm
OPTIONAL EXTRAS
FTS008 Solterian Letter-plate - FD30 - Fitted no extra cost
NOR810 Automatic Integrated drop down seal Drop-seal - Extra cost £68.69
Painted door to RAL colour - Extra cost £147.00
Painted frame to RAL colour - Extra cost £129.50
69 x 18 B/N MDF Architrave to both sides - Extra cost £61.25

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Request Pricing

Tell us your requirements and we will review your specification against certified fire door systems.
Our team ensures compatibility, correct fire rating, and full documentation before issuing your quote.

NOTE: Our customer service team may be assisting other callers.
If you’re unable to reach us by phone, please email sales@premierfiredoors.com
A member of our team will provide a quotation as soon as possible.

Compliance & Certification

Fire doors must be fully traceable and supported by valid test evidence. All our products are backed by third-party certification and supplied as part of a compliant, tested system, not individual components.

Installation Guidance

Correct installation is essential to achieving fire performance. We provide technical guidance to ensure your door is installed in line with tested evidence, BS standards, and manufacturer requirements.

Delivery & Lead Times

Lead times vary depending on specification, finish, and configuration. We provide clear timelines and updates to support project planning and avoid delays on site.

Fire Doors are a System, not just a Door Leaf.

Compliance is achieved through correct specification, compatible components, and tested assemblies. Incorrect decisions at specification stage often lead to failed inspections, delays, and costly rework. Do not gamble with safety.

Anatomy of a Fire Door System

Every component affects compliance.
Understand how components must work together
as a tested, certified assembly, not a mix of parts.

Ready to specify?

Provide your project details, quantities and specifications and our team will issue a structured quotation based on certified system requirements.

Not sure what you need?

Use our configurator to build a door based on your project requirements. We’ll guide you through key decisions like fire rating, sizing, glazing, and finish, so nothing critical is overlooked.

Supplied from certified, trusted manufacturers